Infrared Measurements | |
Infrared temperature range | -30°C to 900°C (-22°F to 1652°F) |
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) | ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater |
≥ -10°C to < 0°C: ±2°C | |
< -10°C: ±3°C | |
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater | |
≥ 14°F to < 32°F: ±4°F | |
< 14°F: ±6°F | |
IR repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
Display resolution | 0.1°C / 0.1°F |
Distance: Spot | 60:1 (calculated at 90% energy) |
Minimum spot size | 19 mm |
Laser sighting | Offset dual laser, output < 1 mW |
Spectral response | 8 μm to 14 μm |
Response time (95%) | < 500 ms |
Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Contact Measurements | |
K-type thermocouple input temperature range | -270°C to 1372°C (-454°F to 2501°F) |
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) | < -40°C: ±(1°C + 0.2° / 1°C) |
≥ -40°C: ±1% or 1°C, whichever is greater | |
< -40°F: ±(2°F + 0.2° / 1°F) | |
≥ -40°F: ±1% or 2°F, whichever is greater | |
K-type thermocouple | 0.1°C / 0.1°F |
K-type thermocouple repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
Measurement Options | |
Hi/Low alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Switchable celsius and fahrenheit | Yes |
Backlight | Two levels, normal and extra bright for darker environments |
Probe input | K-type thermocouple simultaneous display of probe and IR temperature |
Trigger lock | Yes |
Data storage | 99 points |
Display | Dot matrix 98 x 96 pixels with function menus |
Communication | USB 2.0 |
K-Type Thermocouple Specifications | |
Measurement range (bead probe) | -40°C to 260°C (-40°F to 500°F) |
Accuracy | ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |
Cable length | 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
General Specifications | |
Safety and compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
Storage temperature | -20°C to 60°C (-4°F to 140°F) |
Relative humidity | 10% to 90% RH non-condensing up to 30°C (86°F) |
Operating altitude | 2000 meters above mean sea level |
Weight | 0.322 kg (0.7099 lb) |
Power | 2 AA batteries |
Battery life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on) |
AÇIKLAMA
Ürünlerin teslimat süresi 2-4 haftadır.
Ürünler faturalı olarak tarafınıza gönderilecektir.
Ürünlerimiz 30 gün süreyle Garantilidir.
Ürün iade süresi 14 gün olup, iade durumunda kargo bedeli alıcıya aittir.
Saat 16:00'ya kadar verilen siparişler aynı gün kargoya verilir.
Pazartesi-Cuma 09:00 - 18:00 mesai saatlerimizdir.
Arayıp da bulamadığınız tüm Network ve Server yedek parçalarını tedarik ediyoruz.
(Cisco, Avaya, Lenova, HP, IBM, Fujitsu, Samsung, Huawei, Enterasys, Juniper, Alcatel, Sun, Qlogic, Dell, Emulex)
Listelenen ürünler stoklarla sınırlı olup, stokta kalmayan ürünlerin tedarik/fiyat değişikliği hakkı firmamıza aittir.